| Sign In | Join Free | My uabig.com |
|
Brand Name : 1stess
Model Number : EnerArk2.0-M
Certification : LVD
Place of Origin : China
MOQ : 1 piece
Price : negotiable
Supply Ability : 10 containers per month
Delivery Time : 45-60 days
Packaging Details : container
Operating Temperature : -20°C To 50°C
Certifications : IEC,UN,UL
Battery Type : LiFePO4
IP protection : IP55
Installation : Indoor Or Outdoor
Application : Industrial And Commerical
Warranty : 5 Years
Capacity : 107.52KWH-125.44KWH
| Model | EnerArk2.0-NBN-P50 | EnerArk2.0-NBN-P100 |
|---|---|---|
| DC side Parameters | ||
| Cell type | LFP-280Ah | |
| Module model | IP20S | |
| Battery capacity range | 143.36kWh~215kWh | 215kWh |
| AC On-Grid Side Parameters | ||
| Grid connection type | 3P4W | |
| Charging/discharging power | 50kW | 100kW |
| Rated grid voltage | AC 400V±15% | |
| Frequency range | 45Hz~55Hz | |
| Rated AC output current | 72A | 144A |
| Power factor | 0.8(Leading)~0.8(Lagging) | |
| Harmonics | ≤3%(at rated power) | |
| AC off-grid side parameters | ||
| Load type | 3P4W | |
| Rated output power | 50kW | 100kW |
| Rated output yoltage | AC400V±1% | |
| Rated output frequency | 50Hz | |
| Rated current | 72A | 144A |
| Frequency accuracy | 0.2Hz | |
| General Parameters | ||
| Dimensions (W*H*D) | 1900mm*2100mm*1330mm | |
| Packing size(W*H*D) | 2100mm*2244mm*1500mm | |
| Maximum weight | 2500kg | |
| Degree of protection | IP55(Battery Cabinet)IP34(Electrical Cabinet) | |
| Cooling method type | Battery Cabinet (air conditioner)&Electrical Cabinet (forced air cooling) | |
| Fire fighting system | FM200 automatic fire extinguishing | |
| Anti-corrosion grade | C3 | |
| Relative humidity | 0-95%(non-condensing) | |
| Operating temperature* | -20℃~50℃ | |
| Altitude** | <2000m | |
| Noise level | ≤75dB | |
| Communication interface | RS485,Ethernet | |
| Communication protocol | Modbus RTU,Modbus TCP/IP | |
| Product standard warranty | 5 years,6000 cycles(0.5C,95%DOD,EOL:70%) | |
| PV Side Parameters (Optional) | ||
| Maximum PV input power | 30kW/60kW/90kW/120kW | |
| MPPT voltage range | 200V-850V | |
| Number of MPPTs | 1/1/2/2 | |
| Number of PV inputs | 1/1/2/2 | |
| Maximum input current | 100A/200A/300A/400A | |
| Certifications | CE(IEC61000,IEC62619,IEC62477),UN3480,UN38.3,MSDS Converter:UK G99,VDE4105,EN50549 Cell:IEC62619,UL1973,UL1642,UL9540A | |




Q1: How does EnerArk-2.0 perform in the extreme dry heat of the Arabian Desert?
A: Similar to the UAE, it operates up to 50°C with derating above 45°C. The cooling system is designed for arid environments.
Q2: Can it be used in remote oil & gas installations?
A: Yes. Its rugged design, C3 protection, and fire suppression (FM200) make it suitable for industrial and potentially hazardous areas.
Q3: Is it compatible with large-scale solar farms (e.g., NEOM)?
A: Yes. Multiple units can be paralleled (up to 60 units) for MW-scale storage, supporting solar smoothing and time-shift.
Q4: How does it handle wide day-night temperature swings?
A: The BMS and thermal management system automatically adjust to temperature variations, ensuring battery health and performance.
Q5: Does it meet SASO standards?
A: We can provide products that comply with SASO requirements for the Saudi market upon request.
Q1: Can it cope with Qatar’s coastal humidity combined with extreme heat?
A: The humidity and temperature ratings cover these conditions. Corrosion protection (C3) handles salty, humid air.
Q2: Is it suitable for stadiums and infrastructure built for major events?
A: Absolutely. It provides peak shaving and backup power, enhancing energy resilience for critical venues.
Q3: How does it handle dusty conditions from construction sites?
A: IP55 protection is essential. For extreme dust, pre-filters and more frequent service intervals are recommended.
Q4: Can it integrate with existing generator sets for hybrid power?
A: Yes. It is designed for seamless generator integration, optimizing fuel efficiency and reducing runtime.
Q5: Are there examples of use in GCC countries?
A: EnerArk systems are deployed across the GCC. References and case studies are available upon request.
A: Yes. Its operating range covers both extremes. The protection ratings ensure performance in sandy/dusty or humid salty air.
Q2: Can it support agricultural communities (kibbutzim) with solar and storage?
A: Perfectly. DC-coupled solar and storage optimize self-consumption for irrigation and farm operations.
Q3: How does it handle potential grid instability?
A: With grid-forming capabilities (in off-grid mode) and fast response, it stabilizes local microgrids.
Q4: Is it compliant with Israeli SI standards?
A: We can work with local partners to ensure compliance with Israeli standards for grid interconnection.
Q5: Can it be monitored remotely from central control rooms?
A: Yes. Ethernet and cloud connectivity enable integration into national or private energy management systems.
Q1: Can the system handle diverse climates from cold Anatolian plains to hot Mediterranean coasts?
A: Yes. The -20°C to 50°C range spans most Turkish climates. Installation practices (e.g., shading in the south) optimize performance.
Q2: Is it suitable for regions with seismic activity?
A: The sturdy cabinet can be anchored to withstand vibrations. For high-risk zones, we recommend a site-specific seismic evaluation.
Q3: Can it help industrial facilities reduce energy costs under Turkey’s tariff structure?
A: Absolutely. ToU arbitrage and peak shaving directly lower electricity bills for factories.
Q4: How does it perform in windy, dusty regions like Cappadocia?
A: IP55 protects against dust. The cabinet’s weight and anchoring prevent movement in strong winds.
Q5: Are CE certifications accepted for grid connection in Turkey?
A: CE is a key requirement. We also support local Turkish standardization processes as needed.
|
|
All in One Energy Storage System Container With 143.36-215KWh Lifepo4 Lithium Battery For Backup Power Images |